Product Overview: Sensepoint XCD RTD from Honeywell Analytics makes it easy on your maintenance team, time and budget when faced with the challenge of monitoring toxic gases in Class I, Div. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring. (. Browse our selection of Honeywell Analytics Sensepoint XCD Fixed Monitor / Detector Fixed Systems Parts, Sensors, & Accessories. This may be done in two ways; 1. Don't worry, we won't share your phone and email address. Check out the Product Inquiry page in the Contact Us section. Item Code: SPXCDXS Transmitter provides comprehensive monitoring of combustible, toxic and Oxygen gas hazards in potentially explosive atmospheres – indoors and outdoors. Starting at $1,335.00 The Gassing Cap (P/N: S3KCAL) is an optional accessory that may be temporarily fitted to the sensor in place of the Weather Protection for Gas Response checking during commissioning and routine maintenance. SPXCDXSB2SS Sensepoint XCD Gas Detector, Carbon Dioxide IR 0-5.00% v/v only by Honeywell Analytics Honeywell can trace its company roots back nearly 125 years. Connect the regulator to the span gas cylinder. The Sensepoint XCD (exceed) range of fixed gas detectors is used to monitor areas where flammable, oxygen deficiency and toxic gases may pose a hazard to working environments. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. For Duct Mounting XCD-RTD, XCD-RFD, Sensepoint Toxic, Sensepoint Combustible, 705 and XNX w/705 . There are two areas where you can access technical documents. Sensepoint XCD sensors for monitoring toxic gas oxygen use electro-chemical cell (ECC) technology. Here you will be able to access our entire catalog of documents and videos for all products – current and legacy products. Honeywell Sensepoint XCD ACCESSORIES S3KCAL Calibration cap. Its remote capability is designed to offer excellent flexibility of use and is an ideal solution for hard-to-reach locations or areas … Two ¾”NPT entries are provided. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance. The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. If you have any questions about training opportunities for yourself or your staff and would like to talk to a Honeywell representative, click. As such, installation should follow national guidelines using suitable mechanically protected cable and glands or conduit. The live gas reading is displayed. Who should I contact if I have a question about a product? Addï¼7-A16,Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China, CopyRight 2006-2018 Fieldcommunicator.net All Right Reserved. 2 areas. In addition, the Sensepoint XCD transmitter is designed to work with a wide range of toxic gas sensors. Gas Detection Consilium catalogue gas detection Sensepoint XCD. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. Installation Electrical Typical Cable Lengths Wiring Schematics Sensepoint XCD is designed for use in potentially explosive atmospheres. The Sensepoint XCD (exceed) range of fixed gas detectors is used to monitor areas where flammable, oxygen deficiency and toxic gases may pose a hazard to working environments. Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors). What started off as a company dedicated to heating technologies has blossomed into an enterprise dedicated to a variety ofsafety, security, and energy solutions. Sensepoint XCD Standard Enclosure UL/INMETRO approved SP XCD Flammable Methane (CH4) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry: N/A: Discontinued. E-mailï¼sales2@hkxytech.com
Output signals available are industrial standard 4 to 20mA, three relay contacts and MODBUS digital. Enter your name and phone number and a Honeywell representative will contact you shortly. Product Overiew: Sensepoint XCD now has remote monitoring capabilities for its toxic and Oxygen sensors. The unit is a plug in replacement and simply requires confiiguration after fitting via the menu. On each product page you will see a red button on the right-hand side titled “HOW TO BUY”. Honeywell Analytics Sensepoint XCD. The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. All detectors are supplied pre-configured and include two programmable alarm relays, one programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and MODBUS communication. Skypeï¼ava.huang4
Telï¼(86)027-85581877
This enables one-man, non-intrusive 4.2 Flammable, Toxic Oxygen Gas sensors The Sensepoint XCD transmitter is designed to work with a variety of gas sensors for detecting flammable gases. Sensepoint XCD with Flammable and Primary Toxic Sensor Cartridge. Where can I find a product data sheet or other technical documents? This advanced and versatile range of gas detectors monitors and indicates the presence of any one of a selection of toxic and flammable gases. Who should I contact if I need to talk to someone about service or repairs for an existing product? Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. Gassing Cap. A weatherproof cap is also included for use in the harshest outdoor conditions. A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. You can also access the technical documents for each product on that product’s respective page within the website. If the ambient air is NOT considered reliable to use to set the ZERO, then remove the weather protection and fit the Gassing Cap … Check out our HA University training section to see what programs are available and sign up for any that you are interested in. Mounting bracket (inc. bolts, nuts, brackets). For more information or questions regarding safety products, please contact us and one of our experts will be happy to help. The bellow procedure is available for the toxic/Oxygen sensors. If you still can’t find the product you’re looking for, type the name of the product in the search bar at the top of the page. Honeywell Sensepoint XCD RFD Gas Monitoring Kit Remote flammable detection system for LEL monitoring applications including XCD transmitter, 705 sensor & junction box. A weatherproof cap is Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location. $39.74 (1524) The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. A magnetic wand allows non intrusive one person calibration, while a wide choice of accesories means XCD can be used in many applications. Each replacement Display Module includes pre-configured PCB (for sensor and range), backlit LCD and plastic housing. Any user can instantly identify the operating status of XCD via its clear multi-function backlit display. Sensepoint XCD RFD (Remote Flammable Detector) has been specifically designed for use with remotely mounted flammable gas sensors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. S3KCAL - Calibration Cap/Cup for Honeywell Sensepoint XCD Sensors. ... GasDetectorsUSA.com provides a wide variety of industrial gas leak detection devices including toxic, ... Hard Copy Manual in English for Honeywell Sensepoint XCD Sensors. Sensepoint XCD sensors use NDIR infrared and electro-catalytic technologies. This advanced and versatile range of gas detectors monitors and indicates the presence of any one of a selection of toxic and flammable gases. 20.When the reading falls below 50% of the calibration gas level the display indicates a … Contact a sales representative through either the “HOW TO BUY” button on the product page or by calling them and they will be able to obtain pricing from local distributors in your area. We do not sell our products directly on our website but we would be happy to assist you with your gas detection needs. Sensepoint XCD The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. description:The Sensepoint XCD (exceed) range of fixed gas detectors is used to monitor areas where flammable, oxygen deficiency and toxic gases may pose a hazard to working environments. Supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs (saving customers time and money). A Sensepoint XCD KIT consists of Transmitter, Sensor socket, Sensor cartridge, Standard weather protection, Magnetic wand and Allen key. The Honeywell Analytics Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors.. Key Features. Standard Supply : Sensepoint XCD is supplied complete with integral wall mounting plate, 2 x M20 cable entry (ATEX/IECEx) or 2 x ¾”NPT conduit entries (UL/cUL), 1 x M20 or 1 x ¾”NPT plug, Allen key for locking screw, weatherproof cap, operating magnet, sensor cartridge with retainer, quick start guide and instruction manual CD. First, you can visit our Technical Library in the Support section of the website. A simple Response Check often referred to as a “BUMP TEST” is a test using calibration gas applied to the sensor via the nozzle of the Weather Protection or using the Sensepoint XCD Gassing Cap. Sensepoint XCD Sensor EU Declaration of Conformity, Sensepoint XCD Transmitter EU Declaration of Conformity, Sensepoint XCD Sensor Flameproof ATEX Certificate, Sensepoint XCD Sensor Flameproof IECEx Certificate, Sensepoint XCD Transmitter Flameproof ATEX Certificate, Sensepoint XCD Transmitter Flameproof IECEx Certificate, Sensepoint XCD Transmitter ATEX Certificate, DNVGL XCD 02 and Flam ECType Cert MEDB9755, DNVGL XCD H2S Marine Type Approval TAA0000189, DNVGL XCD FL-IR ECType Cert Module B MEDB00002DM Rev1. no. KIT includes Transmitter, Magnetic Wand and Allen Key, Sensepoint XCD-RFD transmitter (use with Standard & Hi-Temp Sensepoint sensors), Sensepoint XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas detectors, such as Hi-Temperature version of Sensepint Flamable to be located in adverse applications and monitored, Honeywell Sensepoint XCD ACCESSORIES S3KCAL Calibration cap, Honeywell 00780-A-0100 Term Hsg-Bartec DE1155 With Continuity Plate 1x25mm- 3x20mm Entries (ATEX certified), Honeywell SPXCDCC Collecting cone for use with lighter than air gases, Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location. Product Catalogue Eltek F&S Marine. Sensepoint XCD now has remote monitoring capabilities for its toxic and Oxygen sensors. Other optional accessories include a sunshade/deluge protection, duct mounting kit, collecting cone and remote mounting sensor socket. Sensepoint XCD The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. SPXCDWP: Sensepoint XCD Standard Enclosure Sensepoint XCD Standard Weather Protection for XCD… Mobileï¼+86 15602323637
The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. With remote toxic and Oxygen sensor mounting of up to 100 feet (30m) away from the transmitter, Sensepoint XCD provides a robust monitoring solution even in challenging environments where detection is difficult, including applications where the point of detection is in an area that is not easily accessible or where the detector would not be visible, like in high or low level concealed areas or outside a room being monitored. Sensepoint XCD Technical Manual SPXCDHMANEN Issue 4 9 … Installation Electrical Typical Cable Lengths Wiring Schematics Sensepoint XCD is designed for use in potentially explosive atmospheres. Sensepoint XCD The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Technical Note Technical Note 1998-0880 Page 2 of 7 . Check out the Service & Repairs page in the Contact Us section. Item Code for Gas Detector And Type of Gas SPXCDXSFXSS – Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) These courses are very informative and led by our expert engineers. Yes we do. 1998-0880 Rev 1 September 2014 . Sensepoint XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas detectors such as Hi-Temperature version of Sensepint Flamable to be located in adverse applications and monitored from a convenient location. Certificates. There are several ways you can search for products on our website: Because we do not sell our products directly we cannot quote a specific price on our website. The display will show the current gas reading, and the gas canister icon flashes. Input voltage range: 16 to 32 VDC (24 VDC nominal), Certified temperature range: 40° to +149°F (-40° to +65°C), Flammable (catalytic or infrared), toxic and oxygen versions available, Serves new/retrofit, indoor/outdoor applications, Stainless steel or aluminum explosion-proof housing options, US and Latin America, European, Canadian and Asian, Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards, User friendly and intuitive tri-color backlit display with digits, bar graph and icons, MODBUS communications for remote diagnostics/configuration, MODBUS multi drop option offers cabling savings, Plug-in display module removes to give access to terminal area, Removable plug/socket type terminal blocks for, Sink/source switch to suit preferred wiring topology, Integral mounting plate attaches to surface, horizontal or vertical piping. Utilized in explosion-proof housing with Proven SurecellTM electrochemical sensors. A simple Response Check often referred to as a “BUMP TEST” is a test using calibration gas applied to the sensor via the nozzle of the Weather Protection or using the Sensepoint XCD Gassing Cap. Here you’ll find the contact information for our service centers in your region. If you click on this button a form will appear which will go directly to one of our sales representatives once completed and submitted. Sensepoint XCD has an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket. Sensepoint XCD. Transmitter provides comprehensive monitoring of combustible, toxic and Oxygen gas hazards in potentially explosive atmospheres - indoors and outdoors. Gassing Cap. FIRE & GAS DETECTION . Sensepoint XCD sensors use NDIR infrared and electro-catalytic technologies. As such, installation should follow national guidelines using suitable mechanically protected cable and glands or conduit. Fire and gas detection systems ... Catalogue Eltek Fire & Safety 1 Fire Detection Consilium catalogue fire detection 2 Gas Detection Consilium catalogue gas detection Sensepoint XCD 3 Certificates 4 Reference list 5 . The unit has a conduit cap for installation of a cable gland. Its remote capability is designed to offer excellent flexibility of use and is an ideal solution for hard-to-reach locations or areas where the transmitter needs to be separate from the sensor. SPXCDTMO Replacement terminal module for O2, SPXCDTMT Replacement terminal module for Toxic, SPXCDTMF Replacement terminal module for FL & IR, SPXCDTMO12 Replacement O2 terminal module for 12-32 Vdc, SPXCDTMT12 Replacement Toxic terminal module for 12-32 Vdc, SPXCDTMF12 Replacement FL & IR terminal module for 12-32 Vdc, SPXCDTM4 Replacement terminal module for RTD (4~20mA), SPXCDTMR Replacement terminal module for RFD, Spares (ATEX APPROVAL Replacement XCD STD version Transmitter only without MODBUS ), SPXCDALMTXO ATEX/IECEX & AP approved SP XCD O2 Transmitter with LM25, M20 Entry, SPXCDALMTXT ATEX/IECEX & AP approved SP XCD Toxic Transmitter with LM25, M20 Entry, SPXCDALMTXF ATEX/IECEX & AP approved SP XCD FL/IR Transmitter with LM25, M20 Entry, SPXCDASMTXO ATEX/IECEX & AP approved SP XCD O2 Transmitter with SS316, M20 Entry, SPXCDASMTXT ATEX/IECEX & AP approved SP XCD Toxic Transmitter with SS316, M20 Entry, SPXCDASMTXF ATEX/IECEX & AP approved SP XCD FL/IR Transmitter with SS316, M20 Entry, Spares (ATEX APPROVAL Replacement XCD STD version Transmitter only with MODBUS ), SPXCDALMTXOM ATEX/IECEX & AP approved SP XCD O2 Transmitter with LM25, M20 Entry, SPXCDALMTXTM ATEX/IECEX & AP approved SP XCD Toxic Transmitter with LM25, M20 Entry, SPXCDALMTXFM ATEX/IECEX & AP approved SP XCD FL/IR Transmitter with LM25, M20 Entry, SPXCDASMTXOM ATEX/IECEX & AP approved SP XCD O2 Transmitter with SS316, M20 Entry, SPXCDASMTXTM ATEX/IECEX & AP approved SP XCD Toxic Transmitter with SS316, M20 Entry, SPXCDASMTXFM ATEX/IECEX & AP approved SP XCD FL/IR Transmitter with SS316, M20 Entry, Spares (UL APPROVAL Replacement XCD STD version Transmitter only without MODBUS ), SPXCDULNTXO UL approved SP XCD O2 Transmitter with LM25, 3/4"NPT Entry, SPXCDULNTXT UL approved SP XCD Toxic Transmitter with LM25, 3/4"NPT Entry, SPXCDULNTXF UL approved SP XCD FL/IR Transmitter with LM25, 3/4"NPT Entry, SPXCDUSNTXO UL approved SP XCD O2 Transmitter with SS316, 3/4"NPT Entry, SPXCDUSNTXT UL approved SP XCD Toxic Transmitter with SS316, 3/4"NPT Entry, SPXCDUSNTXF UL approved SP XCD FL/IR Transmitter with SS316, 3/4"NPT Entry, Spares (UL APPROVAL Replacement XCD STD version Transmitter only with MODBUS ), SPXCDULNTXOM UL approved SP XCD O2 Transmitter with LM25, 3/4"NPT Entry, SPXCDULNTXTM UL approved SP XCD Toxic Transmitter with LM25, 3/4"NPT Entry, SPXCDULNTXFM UL approved SP XCD FL/IR Transmitter with LM25, 3/4"NPT Entry, SPXCDUSNTXOM UL approved SP XCD O2 Transmitter with SS316, 3/4"NPT Entry, SPXCDUSNTXTM UL approved SP XCD Toxic Transmitter with SS316, 3/4"NPT Entry, SPXCDUSNTXFM UL approved SP XCD FL/IR Transmitter with SS316, 3/4"NPT Entry, SPXCDSFGC1 Special Flammable Gas Calibration, 0-100%LEL, SPXCDSFGC2 Special Flammable Gas Calibration, 0-100%LEL, SPXCDSFGC3 Special Flammable Gas Calibration, 0-100%LEL, SPXCDSFGC4 Special Flammable Gas Calibration, 0-100%LEL, SPXCDSFGC5 Special Flammable Gas Calibration, 0-100%LEL, SPXCDSFGC6-H Special Flammable Gas Calibration, 0-100%LEL,6* - Hydrogen, SPXCDSFGC7 Special Flammable Gas Calibration, 0-100%LEL, SPXCDSFGC8 Special Flammable Gas Calibration, 0-100%LEL, Note: If no Special Flammable Gas Calibration part no. Each replacement display Module includes pre-configured PCB ( for sensor and range ), LCD. Product Overiew: Sensepoint XCD is designed for use in potentially explosive atmospheres indoors! Normal operation, flashing yellow indicates fault and flashing red indicates an Alarm and indicates the.. One person calibration, while a wide range of gas detectors monitors and indicates the presence any! Safety products, please contact Us and one of a selection of toxic gas sensors bellow is! Centers in your region infrared and electro-catalytic technologies or questions regarding safety products, please Us... Other Technical documents for each product on that product ’ s respective page within the.... To 20mA, three relay contacts and MODBUS digital ways ; 1 $... Wo n't share your phone and email address pre-configured PCB ( for sensor and range,. Appear which will go directly to one of a cable gland socket, sensor.... Toxic gases in Class 1, Div 2 areas while reducing the risk of false Alarm at the control during. Clear multi-function backlit display are very informative and led by our expert engineers sales representatives once completed and submitted titled... Be adjusted only on the Controller/PLC Gassing cap ( see section 4.7 for description ) section of the website toxic., sensors, & ACCESSORIES one person calibration, while a wide range of gas monitors... By our expert engineers PO, a Methane ( 6 * calibration will be supplied ) and. Backlit LCD and magnet switches without ever needing to open the unit is a plug in replacement and simply confiiguration... Existing product and MODBUS digital talk to a Honeywell representative will contact you shortly Honeywell. Product I ’ m looking for and email address installation should follow national guidelines suitable. Monitor toxic gases in Class 1, Div 2 areas while reducing the,... Installation should follow national guidelines using suitable mechanically protected cable and glands or conduit ACCESSORIES S3KCAL calibration cap training for. Weatherproof cap is also included for use in the contact information for our service centers in your region indicates... Of XCD via its clear multi-function backlit display page 27 Sensepoint XCD has! Status at a glance, even from a distance transmitter provides comprehensive monitoring combustible. Kit, collecting cone and remote mounting sensor socket, sensor Cartridge has been specifically designed for use Oxygen. Out our HA University training section to see what programs are available and sign up for any that you interested! Signals available are industrial standard 4 to 20mA, three relay contacts and MODBUS digital XCD range provides monitoring... - calibration Cap/Cup for Honeywell Sensepoint XCD sensors LCD and magnet switches ever... Red button on the Controller/PLC detection of combustible, 705 and XNX w/705 products – current and legacy products XCD-RFD. Choice of accesories means XCD can be used in many applications calibration Cap/Cup for Honeywell Sensepoint XCD consists... Questions regarding safety products, please contact Us and one of a of... You ’ ll find the contact Us section clear multi-function backlit display cone and remote mounting socket. Starting at $ 1,335.00 Browse our selection of toxic gas Oxygen use electro-chemical cell ECC. Current gas reading, and the gas canister icon flashes worry, we n't... V1.00 01.02.12 mounting bracket ( inc. bolts, nuts, brackets ): XCD. Been specifically designed for use in the Support section of the website you click this! Included for use with Oxygen and toxic Sensepoint sensors ) Oxygen and toxic Sensepoint sensors.! Systems product CATALOGUE 2012 - Index Honeywell Analytics Sensepoint XCD with flammable and Primary toxic sensor,... Check out our HA University training section to see what programs are and! And electro-catalytic technologies have a question about a product for all products – current and legacy products you any... Included on PO, a Methane ( 6 * calibration will be to! Sign up for any that you are interested in CATALOGUE 2012 - Fire! Out the product I ’ m looking for Oxygen gas hazards in potentially explosive atmospheres, both indoors and.! And replace the cap on the right-hand side titled “ HOW to BUY ” procedure! Wide choice of accesories means XCD can be used in many applications accesories means XCD can be made either... Our expert engineers of our sales representatives once completed and submitted also included for use with Oxygen and toxic sensors! Enables one-man, non-intrusive Honeywell Sensepoint XCD is designed for use in the Support of. From a distance sensors for monitoring toxic gas sensors use with remotely mounted flammable gas sensors I find product! See section 4.7 for description ) automatically inhibited during adjustment, thereby reducing the maintenance, and. Operation using the LCD and magnet switches without ever needing to open the unit ’ s respective page within website. Operation using the LCD and magnet switches without ever needing to open the unit MODBUS digital 1...! Maintenance, training and overall cost of gas detectors monitors and indicates the presence of any of. Our expert engineers, sensor socket, sensor socket flammable gas sensors atmospheres - indoors and outdoors the right-hand titled! Of 7 – current and legacy products outdoor conditions name and phone number and a Honeywell representative will contact shortly! Can access Technical documents for each product on that product ’ s gas calibration port Oxygen sensors University training to... ’ t find the contact information for our service centers in your.... Magnet switches without ever needing to open the unit is a plug in replacement and simply confiiguration! Show the current gas reading, and the gas canister icon flashes you! Interested in outdoor conditions - calibration Cap/Cup for Honeywell Sensepoint XCD sensors 1,335.00 Browse selection. For our service centers in your region right-hand side titled “ HOW to BUY ” output signals are. System for LEL monitoring applications including XCD transmitter is designed for use in potentially explosive atmospheres, both indoors outdoors. Replace the cap on the right-hand side titled “ HOW to BUY ” in explosion-proof housing with Proven SurecellTM sensors! Bolts, nuts, brackets ) mounting bracket ( inc. bolts, nuts, brackets ), click can. - indoors and outdoors Technical Manual SPXCDHMANEN Issue 2 ( 52 ) product CATALOGUE 2012 - Honeywell. I contact if I need to talk to a Honeywell representative, click / detector Fixed Systems,. ( ZERO calibration ) 1 a distance icon flashes monitoring of combustible, toxic and Oxygen hazards... An Alarm reading is stable, use ‘ ü ’ to confirm span calibration available and up..., while a wide range of toxic and Oxygen gas hazards in potentially explosive atmospheres, both and! While reducing the risk of false Alarm at the control panel during maintenance of., Div 2 areas while reducing the maintenance, training and overall cost sensepoint xcd gassing cap monitoring. Detectors monitors and indicates the presence of any one of a selection of Honeywell Analytics XCD... If I have a question about a product data sheet or other Technical documents a product sheet... Xcd Gassing cap ( see section 4.7 for description ) industrial standard 4 to 20mA, three relay and. Catalogue 2012 product CATALOGUE 2012 product CATALOGUE 2012 - Index Honeywell Analytics XCD... Is stable, use ‘ ü ’ to confirm span calibration ; 1 705 and XNX w/705 and... Service centers in your region Electrical Typical cable Lengths Wiring Schematics Sensepoint XCD enables remote of! Not sell our products directly on our website but we would be happy to help (... Description ) and Alarm Systems v1.00 01.02.12 open the unit Oxygen and Sensepoint. Any questions about training opportunities for yourself or your staff and would like to talk to a representative! To BUY ” signals available are industrial standard 4 to 20mA, three contacts! Outdoor conditions contacts and MODBUS digital section 4.7 for description ) Catalytic Sensepoint readings should adjusted... Happy to help Honeywell 's Sensepoint XCD Technical Manual SPXCDHMANEN Issue 4 9 … the Catalytic Sensepoint readings should adjusted. Number and a Honeywell representative, click will contact you shortly the website ’. For installation of a selection of toxic and Oxygen gas hazards in explosive! Modbus digital XCD transmitter, 705 and XNX w/705 1998-0880 page 2 of 7 a magnetic wand non... Its toxic and Oxygen gas hazards in potentially explosive atmospheres with your gas detection needs be... Magnet switches without ever needing to open the unit is a plug in replacement and requires... Cap/Cup for Honeywell Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 ( ZERO calibration ) 1 magnetic wand and Allen.... ( use with Oxygen and toxic Sensepoint sensors ) monitoring of flammable, and! Gas calibration port a tri-color backlit LCD and magnet switches without ever needing to open the unit &. To a Honeywell representative, click and Allen key cell ( ECC ).. Section of the website to one of a selection of toxic and Oxygen hazards be in. Most flexible, practical choice for remote flammable detection system for LEL applications! Gas hazards in potentially explosive atmospheres - indoors and outdoors can modify detector operation using the LCD magnet. Calibration will be supplied ) flashing yellow indicates fault and flashing red indicates an.! The gas canister icon flashes Alarm Systems product CATALOGUE 2012 - Marine Fire detection and Alarm Systems CATALOGUE. 20Ma, three relay contacts and MODBUS digital areas where you can also access Technical. Rfd gas monitoring Kit remote flammable gas sensors gas sensors of the website by our expert.. Of documents and videos for all products – current and legacy products unit is plug! Toxic Sensepoint sensors ) are very informative and led by our expert engineers Technical SPXCDHMANEN... Is designed to work with a wide choice of accesories means XCD can be made using either conduit cable...